Modular NCM and LFP battery platform
Standard Pack for buses and trucks
Standard Pack is a modular battery platform for commercial vehicles. Pack S integrates cell stacks, thermal management, cell monitoring and electrical interfaces. Packs are connected in series to form strings; parallel connections between strings provide application-specific system configurations for buses and trucks.

DESIGNED AS A SYSTEM
System architecture and integration.
800 × 600 × 150 mm
Target platform dimensions
Pack S platform dimension target
30 min
Target fast-charging time
Fast charging target: 10–80% SOC in 30 min. Charging depends on operating conditions.
499.2 kWh
Bus reference system
Reference application · Conceptual vehicle integration
332.8 kWh
Truck reference system
Reference application · Conceptual vehicle integration
01
Pack S: the common platform
Cell stacks, thermal management, cell monitoring, protection functions and HV/LV interfaces are integrated into a common platform.
02
Configurable system voltage and capacity
Connecting packs in series increases voltage; connecting strings in parallel increases capacity. The film presents a bus reference configuration with six Pack S per string and four strings connected in parallel.
Reference application · Conceptual vehicle integration
03
Integration on the bus roof or beneath the truck frame
The reference integration concepts position the battery system on the bus roof or beneath the truck frame.
Reference application · Conceptual vehicle integration
ENGINEERING DATA
Configurations and technical data.
Review the specifications for each configuration, including reference conditions and development targets.
Pack S · Shared platform targets
Development programme · Specification targets
| Target platform dimensions | 800 × 600 × 150 mm |
|---|---|
| Chemistry variants | NCM 1P30S / LFP 1P36S |
| Target fast-charging time | 30 minFast charging target: 10–80% SOC in 30 min. Charging depends on operating conditions. |
| Vehicle architecture compatibility | 800 VArchitecture compatibility; not the nominal voltage of every reference system. |
| Safety development objective | No thermal propagation for 24 h after a thermal eventSafety development target |
| Regulatory compliance target | EU Battery RegulationCompliance target |
Pack S · NCM 1P30S
Development programme · Specification targets
| Pack energy content | 20.8 kWh |
|---|---|
| Nominal pack voltage | 112.3 V |
| Approximate pack energy density | 200 Wh/kgApproximate |
| Estimated service life | 1.5 million kmEstimated |
Pack S · LFP 1P36S
Development programme · Specification targets
| Estimated pack energy density | 156 Wh/kgEstimated |
|---|---|
| Estimated service life | 2 million kmEstimated |
Bus reference · One series string
Reference application · Conceptual vehicle integration
| Packs per string | 6 × Pack S |
|---|---|
| Physical arrangement | 3 across; 2 layers |
| String energy content | 124.8 kWh |
| Nominal string voltage | 673.8 V |
Bus reference · Roof installation
Reference application · Conceptual vehicle integration
| Parallel strings | 4 |
|---|---|
| Total number of Pack S units | 24 |
| Reference system energy | 499.2 kWh |
| Nominal voltage | 673.8 V |
| Pack orientation in plan view | 90° |
Truck reference · Installation beneath the frame
Reference application · Conceptual vehicle integration
| Packs per string | 4 × Pack S |
|---|---|
| Strings beneath the frame | 4; two strings on each side |
| Reference system energy | 332.8 kWh |
| Nominal voltage | 449.2 V |
PRODUCT FILM
Architecture and integration in detail.
Our engineering film presents the system architecture, vehicle integration concepts and reference configurations.
Film in English. Key technical information is available in the tables above.
CONTACT OUR TEAM
Discuss your battery project.
Tell us about your vehicle platform, operating profile and battery requirements. Our European team supports battery selection, system development and vehicle integration.